Sign In | Join Free | My xuijs.com
China Beijing Zetron Technology Co., Ltd logo
Beijing Zetron Technology Co., Ltd
Beijing Zetron Technology Co., Ltd for better life
Verified Supplier

5 Years

Home > Exhaust Gas Analyzer >

Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide

Beijing Zetron Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide

  • 1
  • 2

Brand Name : Zetron

Model Number : PTM600

Certification : CE, ISO13485, ISO9001

Place of Origin : China

MOQ : 1

Payment Terms : T/T, L/C, Western Union, MoneyGram

Supply Ability : 1000 set/month

Delivery Time : 3-7 days

Packaging Details : Plastic case

Product Name : Portable Infrared Biogas Analyzer

Type : Biogas analyzer

Detecting Gas : CH4, CO2, O2, H2S

Display mode : 3.5 inch color screen

Sensor type : Infrared Sensors Imported

Connection : Wi-Fi/USB Network

Size : 230*210*120 mm (L*H*W)

Weight : 2.5(kg)

Contact Now

PTM600-Bio Portable Biogas Analyzer
OVERVIEW
PTM600-Bio designed to meet Global Renewable Energy and Carbon Credit digester project requirements, it is the ideal field instrument for anaerobic digester gas analysis. Easy-to-use and portable, the PTM-Bio measures gas composition and flow with repeatable accuracy on farms, food processing plants and waste water treatment facilities.
PTM600 can be used in accurate detection and analysis of a variety of gas concentration and measurement of environmental temperature and humidity. It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. It is possible to simultaneously detect 1 ~ 6 types of gases, which can be expanded to 18 or more types of gases, and the types for detection are more than 500 types.

FEATURES
· Temperature and humidity measurement function
· 1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1 meter)
· High temperature sampling and cooling filter handle
· High temperature humidity pretreatment system
· External remote sampling pump
· Multiple humidity dust filter
· CD-ROM (upper level computer communication software)
·SD card storage
·USB disk storage
· External mini wireless infrared printer
· Built-in mini printer
· Wireless data communications: RS232, infrared communication, automatic recognition
APPLICATION SCENES
It's suitable for all levels of traffic, public security testing stations, environmental protection exhaust control points at all levels, teaching laboratories of colleges and universities, automobile manufacturers, engine manufacturers, motorcycle manufacturing areas, as well as the use of one, two and three types of automobile repair plants, 4S shops, automobile repair and maintenance departments.
SPECIFICATION

Gases to be detected Arbitrary combination of 1 ~ 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.
Optional configuration: temperature and humidity measurements.
Detection range 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized.
Resolution 0.01ppm or 0.001ppm (0 ~ 10 ppm)
0.01ppm (0 ~ 100 ppm)
0.1ppm (0 ~ 1000 ppm)
1ppm (0 ~ 10000 ppm or more)
0.01 mg/l (0 ~ 200 mg/l)
0.1% LEL
0.01%LEL
0.001% Vol
Detection principle Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service life Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years;
catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Allowable error ≤±2% F.S (other or higher precision levels can be customized)
Linearity ≤±2% Repeatability ≤±2% Uncertainty ≤±2%
Response time T90≤20 seconds Recovery time ≤30 seconds
Working environment Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature -40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Power supply 3.6VDC, 10000mA high capacity rechargeable polymer battery
Display mode 3.5-inch high-definition color screen
Alarm mode It is possible to set as sound & light alarm, vibration alarm, turning off the alarm.
Protection level IP66
Explosion-proof mark Exia II CT6
Exterior dimensions 230×210×120 mm (L×H×W)
Weight 2.5Kg

Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide

Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide


Product Tags:

usb exhaust gas analyzer

      

infrared sensors exhaust gas analyzer

      

measuring methane carbon dioxide biogas analyzers

      
Best Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide wholesale

Zetron PTM600-Bio Exhaust Gas Analyzer For Measuring Methane And Carbon Dioxide Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Zetron Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0